TGP-503 Polymer Cement Waterproof Coating
Classification:
Keywords: TGP-503 Polymer Cement Waterproof Coating
immediate consultationDetailed description
Product Introduction
Zhuozhongzhizhong brand TGP-503 polymer cement waterproof coating is made from the latest room temperature rapid cross-linking technology, using elastic acrylic copolymer emulsion mixed with various high molecular additives. It can be used by mixing with cement in a certain proportion during construction. This waterproof coating has excellent impermeability, crack resistance, durability, and acid and alkali resistance. The product is non-toxic, has no environmental pollution, and is easy to apply, making it a new generation of environmentally friendly waterproof coating.
Product Characteristics
1. The film has high tensile strength and good water and weather resistance.
2. Can be applied on both dry and wet substrates, with strong adhesion.
3. Cold application, easy to operate, and not restricted by the moisture content of the substrate, which can shorten the construction period.
4. Water-based coating does not require open flames, posing no safety hazards during construction.
Scope of Application
1. Can be used for waterproofing, seepage prevention, and moisture-proofing projects on roofs, exterior walls, bathrooms, kitchens, water tanks, balconies, basements, tunnels, and roads.
2. Can also be used as one layer in multi-layer waterproofing systems.
Technical Performance Indicators: GB/T 23445-2009

Construction Method
1. Substrate Treatment: The surface of the substrate should be flat, solid, free of honeycombs, rough surfaces, dust, oil stains, and other surface attachments. The corners should be rounded, and any defects in the substrate should be repaired before construction to meet waterproofing requirements.
2. Preparation and Application of Waterproof Coating: (Type II) mix emulsion: cement = 1:0.8-0.9 / (Type III) mix emulsion: cement = 1:1 by weight, then apply the prepared coating in multiple thin layers, ensuring the total thickness meets waterproof design requirements, with an interval of about 1-2 hours between each layer (specific adjustments should be made based on weather and environmental conditions, aiming for a non-tacky surface). The direction of the last coat should be perpendicular to the previous coat.
3. Reinforcement Treatment: If reinforcement of the waterproof layer is needed, non-woven fabric or alkali-resistant fiberglass cloth can be used as reinforcement.
4. Consumption per 1mm thickness: 1-1.5kg/㎡.
Precautions
1. Cement should be 325# ordinary Portland cement or slag cement; early-strength cement or quick-setting cement is strictly prohibited.
2. Ingredients should be mixed strictly according to the ratio, stirred evenly, with a stirring time of no less than 5 minutes; manual stirring and adding water is prohibited.
3. Emulsion should be stored sealed at 5℃-40℃, with a shelf life of 12 months.
4. Packaging Specification: 25kg/barrel, 50kg/barrel.
Product Consulting